Arranging a dependable led video panel rental generally costs between $80 and $180 per modular 500x500mm tile per day for standard indoor resolutions (such as P2.6 or P2.9), while outdoor daylight-rated tiles (such as P3.91 or P4.81) typically rent between $70 and $140 per tile daily. When scaled into a complete production setup, a standard 12ft x 7ft corporate display runs from $2,200 to $4,200 per event day, while large outdoor festival concert walls easily surpass $6,000 to $15,000 once staging trusses, structural wind ballasts, and auxiliary diesel power generators are factored in. Securing the right hardware without falling into budget traps comes down to four non-negotiable checkpoints: guarantee at least 5,000 to 6,500 nits of calibrated brightness paired with an IP65 waterproof rating for outdoor daylight (or 1,000 to 1,500 nits indoors); calculate pixel pitch strictly by viewing distance using the one-meter-per-millimeter formula so you do not waste thousands on invisible resolution; establish dedicated three-phase electrical drops or clean generator power with automatic voltage regulation; and always insist on a turnkey “wet hire” contract that provides an experienced video engineer on-site with a 10% module spares float from load-in through final teardown.

Have you ever walked onto an exhibition trade floor, a corporate conference stage, or an outdoor festival meadow, only to see the main video wall looking like a washed-out, milky gray sheet under venue lighting? Or maybe you have seen a high-stakes keynote presentation interrupted because an unshielded network cable on the stage deck got kicked, knocking out four full columns of tiles right in the middle of a live demo. Event managers, production leads, and brand directors face these exact headaches all the time. You commit a massive portion of your budget toward visual technology, yet you end up with equipment that fails to deliver clarity, trips venue power breakers, or cannot handle an afternoon rain shower. What should we do then to make sure our screen investment delivers flawless, broadcast-grade visuals without unexpected invoices? Let’s dive right in!

Anatomy of an LED Video Panel: Cabinets, Modules, and Signal Distribution

When we are using modular visual hardware, many people assume an LED screen is built just like a giant domestic television. In reality, a modern modular display system is an interconnected grid of precision structural, electrical, and optical components engineered for rapid assembly and teardown.

The core structural building block is the die-cast aluminum or magnesium-alloy cabinet. Standard industry rental fleets standardize on two physical form factors: 500mm x 500mm squares (roughly 19.7 inches) or 500mm x 1000mm vertical rectangles. Die-cast manufacturing ensures physical tolerances within fractions of a millimeter, which prevents unsightly light gaps from showing between joined panels.

Inside each cabinet sits four magnetically latched LED modules. These modules contain the surface-mount diodes (SMDs) or Glue-on-Board (GOB) protective resin coatings, alongside internal driver chips that regulate refresh frequency and grayscale depth.

Mounted behind the modules is the central service core:

  • A switched-mode power supply unit (PSU) converting incoming AC line voltage down to low-voltage DC power.
  • A digital receiving card (typically NovaStar A5s Plus, A8s, or Brompton Tessera R2) translating packetized video data into individual diode drive commands.
  • A mechanical fast-locking system consisting of top alignment guide pins, side cam-lock levers, and optional angle-adjustment blocks allowing curved configurations ranging from five degrees concave to ten degrees convex.
Modular LED Cabinet Topology:
┌───────────────────────────────┐
│ [Module 1]  │  [Module 2]     │  <── Precision SMDs / GOB protective resin
├─────────────┼─────────────────┤
│ [Module 3]  │  [Module 4]     │
├─────────────┴─────────────────┤
│ [Hub Board + Receiving Card]  │  <── Color calibration & packet translation
│ [Internal 200W-300W DC PSU]   │  <── High-efficiency switched-mode power
└───────────────────────────────┘

The video processor acts as the primary brain of the video chain. It accepts raw inputs from media playback servers, presenter laptops, or production broadcast switchers via HDMI, DisplayPort, 12G-SDI, or tactical fiber. The processor crops, scales, and maps the incoming video canvas pixel-by-pixel to match the layout of the display wall, outputting signal packets across ruggedized Neutrik EtherCON Cat6 lines.

Indoor vs. Outdoor Rental Requirements: Avoiding Environmental Failure

Treating an outdoor event like an indoor production with the roof removed is the most common cause of hardware failure in the event industry. Indoor and outdoor panels represent two completely distinct hardware categories that should never be substituted for one another.

Engineering ParameterIndoor LED Video Panel RentalOutdoor LED Video Panel Rental
Sustained Optical Brightness800 to 1,500 nits5,000 to 6,500+ nits
Ingress Protection RatingIP30 to IP40 (Dust protected only)Minimum IP65 front, IP54 rear
Standard Pixel PitchesP1.5, P1.9, P2.6, P2.9P3.91, P4.81, P5.95
Panel Cooling ArchitecturePassive aluminum convection heatsinksSealed high-velocity brushless exhaust fans
AC Power Connection TypeStandard PowerCON blue and gray couplersWaterproof Neutrik PowerCON TRUE1 TOP
Data Signal InterfaceStandard RJ45 or light EtherCONIP65 weatherized EtherCON with rubber boots
Wind Load Ballast FactorBasic tip-over counterweightsCalculated deadweight ballast (80 to 120 kg/sqm)

Brightness and moisture sealing represent the dividing line between success and failure.

In an indoor hotel ballroom, a display outputting 1,000 nits delivers vibrant color contrast and rich blacks. Take that same panel outdoors into an open courtyard, and the ambient sunlight (which easily exceeds 30,000 to 80,000 lux) completely overpowers the diodes, turning graphics into a washed-out, illegible gray sheet. Outdoor cabinets utilize high-efficiency LEDs driven at higher current loads to punch through direct midday sunlight.

Moisture resistance is equally vital. True outdoor cabinets feature silicone conformal coating across all printed circuit boards, sealing delicate driver chips against rain, sea mist, and humidity. Cable access ports feature compressed rubber O-rings that prevent water from seeping into high-voltage connections. An indoor cabinet placed inside an open-air tent will pull in damp evening air through its cooling vents, triggering short circuits and permanently destroying receiving cards.

Pixel Pitch Mathematics: Stop Paying for Resolution Your Audience Cannot See

Pixel pitch refers to the center-to-center distance in millimeters between adjacent diode clusters, designated by the letter P (such as P1.9, P2.6, P2.97, P3.91, or P4.81). Smaller numbers represent tighter diode spacing, higher pixel density, and significantly higher rental rates.

A common mistake made by inexperienced event planners is demanding the smallest possible pixel pitch regardless of venue geometry.

The Universal Visual Acuity Rule: Minimum Comfortable Viewing Distance (in feet) ≈ Pixel Pitch (in mm) × 3.28 (roughly one meter of distance per millimeter of pitch).

If your conference layout places the front row of executive seating fifteen feet away from the stage, a P3.91mm display resolves into a smooth, seamless picture where individual pixels are indistinguishable to the human eye. Paying double to upgrade that screen to a delicate P1.9 panel delivers zero visible sharpness to anyone seated in that room. You are effectively paying for microscopic density that human optics cannot resolve at that distance.

Audience Distance vs. Diode Blending Threshold:
[Screen Face] ──── 6 ft (1.8m) ────> P1.9 required for crisp small text
[Screen Face] ──────── 9 ft (2.7m) ────────> P2.6 optimal for slide decks
[Screen Face] ──────────── 13 ft (4.0m) ────────────> P3.91 blends seamlessly
[Screen Face] ──────────────── 18 ft (5.5m) ────────────────> P4.81 delivers high impact

Refresh rate is another quiet specification that directly impacts content quality. Budget hire stock frequently operates at 1,920Hz. While 1,920Hz looks fine to the human eye, videographers filming the stage and attendees recording mobile video will capture rolling horizontal scan lines and severe flickering.

A trick I frequently use when reviewing audiovisual proposals is demanding a minimum 3,840Hz refresh rate (or 7,680Hz for broadcast cameras). This ensures that camera sensors capture smooth, broadcast-clean images without dark scanning artifacts.

Pixel Pitch RatingDiode ConfigurationMinimum Clean SightlineOptimum Screen Size (16:9)Rental Cost MultiplierBest Practical Application
P1.5 – P1.9Mini-LED / COB / GOB4 to 6 feet (1.2 – 1.8m)8ft x 4.5ft to 12ft x 7ft2.5x to 3.5x baselineExecutive boardrooms, high-res broadcast, command suites
P2.6 – P2.9SMD 1515 / 20208 to 10 feet (2.4 – 3.0m)12ft x 7ft to 16ft x 9ft1.8x to 2.2x baselineCorporate keynotes, indoor galas, church sanctuaries
P3.91 (Standard)SMD 1921 / 212112 to 14 feet (3.6 – 4.2m)13ft x 8ft to 24ft x 13ft1.0x (Baseline reference)The undisputed workhorse for live sports & festival stages
P4.81SMD 272716 to 18 feet (4.8 – 5.5m)20ft x 11ft to 33ft x 18ft0.8x to 0.9x baselineLarge outdoor arenas, perimeter ribbons, civic gatherings
P5.95 – P7.8SMD 3535 / Mesh20 to 26+ feet (6.0 – 8.0m)30ft x 17ft and larger0.6x to 0.7x baselineMassive stadium tours, open airfields, transparent facades

Detailed Setup Methods: From Flight Cases to Show Call

How do professional audiovisual crews erect modular screens safely and calibrate video signals properly? Detailed setup methods, let’s take a look together!

Step 1: Laying the Zero-Tolerance Baseline

The assembly process starts on the floor before any display cabinets leave their foam-lined flight cases.

Whether the screen is ground-supported or flown from overhead truss, the bottom support beam must be completely level. Technicians place aluminum ground rails or steel base plates across the stage deck, adjusting high-precision screw jacks while checking a digital spirit level.

If the base rail is off by even two millimeters across a fifteen-foot width, that tilt magnifies as cabinets latch together vertically. By row four or five, cabinet alignment pins begin binding, panels will not lock flush, and delicate corner diodes can crack under mechanical tension.

Step 2: Mechanical Interlocking and Latching

Panels are erected row by row, working outward from the center line to balance weight evenly.

The technician seats the precision guide pins of an upper cabinet into the matching holes of the lower cabinet, engages the vertical cam-lock lever, and latches the horizontal side locks.

Throughout this assembly, technicians wear clean antistatic gloves to prevent skin oils from smudging the matte black shaders. Corner protection tabs on the bottom row of panels remain engaged until the screen structure is mechanically rigid.

Step 3: Power Distribution and Data Looping

Once panels are locked into a rigid grid, power and data cabling begins:

  • AC Power Runs: Panels are daisy-chained using twist-lock Neutrik PowerCON cables. To maintain electrical safety, technicians limit daisy chains to no more than six to eight cabinets per 16-amp breaker circuit, preventing startup inrush currents from tripping power feeds.
  • Data Routing: Heavy-duty EtherCON Cat6 lines snake through cabinet columns in a vertical serpentine sequence. Technicians map pixel counts carefully, keeping data bandwidth below 600,000 pixels per gigabit network port on the video processor to avoid dropped frames.
Closed Data Loopback Architecture:
[Processor Main Port 1] ───> [Tile 1] ───> [Tile 2] ───> [Tile 3] (Primary Feed)
                                                                     │
[Processor Backup Port 2] <──────────────────────────────────────────┘ (Redundant Return)

Step 4: Redundancy Loops and Signal Mapping

Professional staging crews always implement closed data loopback redundancy.

The primary signal line exits Port 1 on the video processor, loops through the display panels, and returns from the final panel back into Port 2 on an alternate output card. If a stagehand accidentally kicks a data cable or an internal connector fails during the event, the backup port takes over within microseconds without a single glitch appearing on screen.

Step 5: Color Temperature Calibration and White Balance

The final technical phase involves dialing in optical uniformity.

The technician runs pure Red, Green, Blue, and White raster test patterns across the entire screen. This step exposes any dead diodes, stuck driver chips, or color binning discrepancies caused by mixing panels from different manufacturing batches. The technician uses optical calibration software to lock the display white point to 6500K, ensuring presenters look natural on camera under stage spotlights.

Rigging Architectures: Ground Stacking vs. Flown Overhead Truss

How your screen is mounted on-site directly impacts your staging space, site safety, and overall hire expenses.

Execution FactorGround-Stacked Support FrameFlown Overhead Truss Rigging
Stage Footprint Consumed4 to 6 feet behind stageZero floor space; hangs clear of stage deck
Structural Hardware NeededSteel base rails, rear pipe truss, ballastAluminum fly-bars, electric chain hoists, steel slings
Venue Approvals RequiredFlat floor check; basic weight clearanceCertified rigging plots, point load sign-offs
Assembly Speed2 to 4 hours4 to 6 hours
Outdoor Wind BallastingHeavy deadweight blocks (80-120kg/sqm)Rapid motor lowering if wind spikes
Cost ProfileLower mechanical and rigging labor feesHigher expenses for hoists, riggers, and venue permits

Ground stacking is the preferred method when ceiling load points are unavailable or when budget constraints rule out motor hoists. However, the rear support legs and counterweights require considerable floor clearance behind the stage backdrop.

Flown screens look exceptionally sleek and leave the stage deck unobstructed, but they require structural engineering sign-offs and certified rigging labor.

Ground-Stack Ballast Distribution:
┌───────────────────────────────┐
│     [LED Display Surface]     │
└───────────────┬───────────────┘
                │  <── Rear Diagonal Steel Pipe Bracing
     ┌──────────┴──────────┐
═════╡ [Weighted Base Leg] ╞══════════════════════════ [Stage Deck]
     │ [80-120kg Ballast]  │ <── Concrete deadweights or heavy steel plates
     └─────────────────────┘

Power Infrastructure: Managing Amperage and Generator Feeds

Underestimating electrical power draw is one of the most frequent causes of event-day blackouts. An LED video wall consumes substantial current, especially during startup or when displaying high-brightness white backgrounds (such as sponsor logos or commercials).

Each standard 500x500mm cabinet typically consumes between 100W and 140W under normal video playback, with peak power spikes reaching 250W to 300W during full-white scenes. A modest 16ft x 9ft display contains around 54 cabinets, meaning the screen can pull 13.5kW to 16.2kW at peak load.

Trying to power that screen from standard domestic wall plugs will trip circuit breakers immediately.

Clean Event Power Flow:
[3-Phase 32A/63A Utility Supply or Silent Generator]
                         │
                         ▼
             [Power Distro Rack (PDU)]
                         │ (16A CEE Breakouts with RCDs)
         ┌───────────────┴───────────────┐
         ▼                               ▼
 [Stage Left Column Runs]     [Stage Right Column Runs]
 (Max 6-8 tiles per circuit)  (Max 6-8 tiles per circuit)

For reliable operation:

  • Indoor venues must provide a dedicated 32A or 63A three-phase industrial supply (such as CEE form or Cam-Lok drops) within 100 feet of the control desk.
  • For outdoor festivals, open parks, or remote lawns, organizers must hire an event-grade whisper-quiet diesel generator (minimum 30kVA to 50kVA).
  • Ensure the generator includes an electronic governor and automatic voltage regulator (AVR) to eliminate voltage dips and spikes that can fry delicate video receiving cards.

Self-Answering Real-World Production Challenges

Let’s address the practical problems that event managers encounter when planning live productions.

What should we do if our ballroom has huge glass windows and bad daylight glare?

Planners often struggle when an exhibition hall or hotel atrium features floor-to-ceiling glass windows without blackout drapes. Some attempt to use high-lumen conference projectors to save money, but ambient daylight washes out projected light, leaving presentation slides unreadable.

The practical fix is renting a compact P2.6 or P2.9 LED wall calibrated to 1,500 nits. Because LED panels emit direct light rather than reflected light, the presentation punches straight through glass reflections, keeping your slides crisp and clear.

Can an indoor-rated LED video panel be safely set up under an open-sided marquee tent?

This is a risky shortcut that often results in ruined equipment.

Even when sheltered from direct overhead rain, an open-sided tent exposes equipment to ambient humidity, morning dew, and windblown dust. Indoor cabinets feature open cooling vents; moisture condenses directly onto bare circuit boards, causing short circuits.

Furthermore, daytime ambient light under an open-sided tent often exceeds 5,000 lux, overpowering standard indoor panels. Always insist on IP65 outdoor-rated gear for any environment lacking four solid, climate-controlled walls.

How do we prevent audio lip-sync delay when running live camera feeds to a big screen?

Because high-resolution video processors take 30 to 60 milliseconds to scale, de-interlace, and map camera signals across custom pixel matrices, the visual feed lags slightly behind live audio. If a speaker’s voice routes directly to the sound system while the video passes through the scaler, the audience will notice a distracting lip-sync mismatch.

The fix is straightforward: instruct your sound engineer to apply an identical 40ms to 60ms delay inside the digital audio mixer to lock sound and vision into alignment. That way, you can keep speech and screen movements locked in perfect alignment.

But some friends want to cut costs by supplying their own volunteers to assemble the tiles; is this safe?

You might be tempted to save labor expenses by having your own team handle the physical stacking while the rental house only drops off the cases.

This is almost always a costly mistake. LED panels are high-value, fragile electronic instruments. If an untrained volunteer bumps a panel edge against a metal truss or forces a latch pin, dozens of tiny diodes can sheer off in a fraction of a second. Rental providers will hold you fully liable for the repair bill, which quickly wipes out any labor savings. Leave panel handling and mechanical rigging to certified audiovisual technicians.

Why do some rental companies discount multi-day bookings while others charge full price?

In the professional audiovisual industry, standard rental contracts apply a multi-day scaling factor. The standard schedule bills Day 1 at 100%, Day 2 at roughly 50%, and Day 3 onward at 25% to 30% of the base day rate. A full seven-day hire typically costs roughly 2.5 to 3 times the single-day equipment price.

If an equipment vendor tries to charge you 100% full rate for every single load-in, setup, and rehearsal day across a four-day booking, push back. The hardware is already sitting inside your venue; it is not being transported elsewhere. While technician labor remains billed at a daily working rate, equipment rates should drop substantially after day one.

Evaluating Rental Quotes: Dry Hire vs. Wet Hire and Hidden Fees

Audiovisual quotations often look confusing because suppliers bundle equipment, logistical freight, and skilled labor in different ways.

Operational Scope Breakdown:
[ Dry Hire ] ──> Bare Panels + Flight Cases (Client assumes all freight, rigging & damage risk)
[ Wet Hire ] ──> Panels + Rigging Truss + Scalers + Cabling + Certified On-Site Technician

The difference between dry hire and wet hire is critical. Dry hire covers only bare flight cases picked up from a warehouse dock. You are responsible for mechanical rigging, electrical compliance, video processor mapping, and damage liability.

Wet hire is an all-inclusive production service. The rental company handles logistics, provides certified rigging hardware, manages power distribution, and stations an experienced display technician at the control desk throughout rehearsals and showtime.

Budget Line ItemBare-Bones Dry HireFull-Service Turnkey Wet Hire
Equipment ProvidedBare panels, basic jumpers, flight casesPanels, ground rails, processors, distro racks
Logistics & DrayageClient arranges trucking and loading dock crewWhite-glove delivery, dock handling, and strike
Technical StaffingZero crew includedCertified lead video engineer + rigging hands
Spare Parts FloatNo backup parts supplied5% to 10% module float and spare power supplies
Signal ProcessingClient supplies switchers and scalersDedicated 4K video processor and distribution
Average Day Cost (16x9ft)$1,800 – $2,800$3,800 – $6,500 (Including crew and support)

Before signing a rental agreement, check your proposal for these common hidden costs:

  1. Overtime Labor Surcharges: Standard labor calls are based on a ten-hour window. If your awards gala runs until midnight and load-out wraps at 2:30 AM, late hours often trigger double-time labor charges unless negotiated upfront.
  2. Drayage and Loading Dock Delays: LED road cases weigh up to 180 lbs each when packed with six panels. If your venue has narrow access corridors, lacks a hydraulic dock leveler, or requires moving gear across grass, additional manual handling labor will be charged.
  3. On-Site Spare Module Allotment: Road transit can rattle module connectors loose. Ensure the contract includes a 5% to 10% spare equipment float on the truck so the technician can swap out a damaged tile in minutes.
  4. Weather Cancellation Clauses: Outdoor events face rain delays and gusting winds. Check how the contract handles weather cancellations. A professional supplier will offer a clear rescheduling credit window rather than keeping your entire deposit.

Grounded Recommendations for Production Teams

From coordinating corporate presentations and outdoor festival stages over the years, my strongest recommendation is simple: never sacrifice on-site technical staffing just to rent a slightly wider screen.

An LED video wall is an active mechanical and electronic deployment, not a passive piece of staging. It combines high-voltage electrical distribution, heavy structural ballast, and complex video processing. Choosing a cheaper dry-hire quote or relying on untrained volunteers leaves you vulnerable if an Ethernet connector fails or a circuit breaker trips mid-event. A dedicated, experienced display engineer sitting at the control rack monitors signal health, balances color temperature on the fly, and fixes small issues before anyone in the audience notices.

Focus on practical visibility over vanity sizing. Prioritize an IP65 rating whenever gear sits near open air. Keep your pixel pitch matched to real-world sightlines, and insist on closed-loop signal redundancy. When those operational details are handled early, your video display becomes a stress-free centerpiece that elevates your entire production.

Hope this guide helps you approach your next screen booking with complete confidence!

FAQ

1. What is the average cost for an led video panel rental?

A standard full-service wet hire package for an indoor 12ft x 7ft P2.6 screen generally ranges from $2,200 to $3,800 per day. Outdoor modular setups (such as a 16ft x 9ft P3.91 display) typically run between $3,500 and $6,000 per day. Larger concert-scale walls (20ft x 11ft) range from $5,500 to $9,500+ daily, covering delivery, certified mounting hardware, video processing, and an on-site technician. Multi-day rentals normally qualify for discounted daily rates.

2. Can outdoor rental panels operate safely in heavy rain?

Yes, provided you booked authentic IP65 weather-rated panels. IP65-certified hardware features silicone-sealed module backings and waterproof twist-lock power and data connectors that operate safely through downpours. However, if storms produce lightning or wind gusts exceeding 30 to 35 mph, safety rules mandate that the display must be powered down and lowered to ground level.

3. What pixel pitch should I choose for an indoor corporate conference?

For indoor ballrooms, awards shows, and corporate conferences, P2.6mm or P2.97mm is the industry sweet spot. This delivers sharp text for slide presentations and clear video playback for attendees seated 8 to 10 feet away, without the higher rental rates of fragile P1.5 micro-pitch panels.

4. What is the practical difference between dry hire and wet hire?

Dry hire provides only the physical display tiles, processors, and road cases, leaving transportation, structural assembly, power configuration, operation, and troubleshooting up to the client. Wet hire is an all-inclusive production service where the rental supplier delivers, rigs, configures, operates, and breaks down the display with certified technicians on-site.

5. What kind of electrical power supply is required on site?

Small indoor screens under 10 feet wide can often run off standard 15A/20A wall outlets split across independent breakers. Larger modular walls (16x9ft or larger) require a dedicated 32A or 63A single-phase or three-phase industrial hookup (such as CEE or Cam-Lok connections). Venues without this electrical capacity require an auxiliary silent diesel generator.

6. Can I use a regular consumer TV outside instead of an led video panel rental?

No. Household consumer TVs produce only 250 to 450 nits of brightness, which washes out completely under ambient daylight. Additionally, consumer units lack environmental seals, meaning outdoor humidity, direct heat, and dust can ruin sensitive internal boards and create shock hazards.

7. How far in advance should I reserve an led video panel rental?

For peak spring and summer festival months, holiday party seasons, and major sporting tournament windows, reserve your screen at least 6 to 10 weeks in advance. For standard indoor corporate presentations during off-peak periods, 2 to 4 weeks of lead time is usually sufficient to finalize site logistics and power checks.

8. What is refresh rate and why does it matter?

Refresh rate measures how many times per second the display hardware redraws video frames. Budget panels run at 1,920Hz, which looks fine to the human eye but produces flickering black lines on phone cameras and video feeds. Specifying a refresh rate of 3,840Hz or higher ensures clean image capture for videographers and social media posts.

9. What ground preparations are required for an outdoor ground-stacked screen?

The setup site must offer level, solid ground (such as asphalt, concrete, or compacted turf) capable of supporting several thousand pounds of concentrated weight. If assembling on soft grass, the crew must lay heavy-duty spreader plates beneath the support feet and stack 80 to 120 kg of counter-ballast per square meter of screen area to prevent wind tip-overs.

10. Who covers the cost if an LED module fails during an event?

If an LED panel experiences internal electronic failure (such as a factory power supply breakdown or receiver card fault) under normal operation, the rental company handles repairs using their on-site spares kit at no added charge. If damage results from guest accidents, liquid spills on indoor gear, or vehicle collisions, the client’s commercial general liability policy or damage waiver covers the repair cost.

Disclaimer
Product information, specifications, and prices are provided for reference only and may vary based on project requirements and market conditions. Brand names mentioned are for comparison purposes only and do not imply any affiliation.For the most accurate product details and pricing, please refer to your specific project requirements.

GET YOUR CUSTOM LED DISPLAY QUOTE

Tell us your basic requirements and receive a quick quotation from our LED experts.

SOLICITE UM ORÇAMENTO PERSONALIZADO PARA SEU PAINEL DE LED

Informe seus requisitos básicos e receba rapidamente um orçamento de nossos especialistas em painéis de LED.

Solicite su presupuesto personalizado de pantalla LED

Indíquenos sus requisitos básicos y reciba rápidamente un presupuesto de nuestros expertos en pantallas LED.