BLOG

 

How Much Does an LED Screen for Stage Rental Cost?

Table of Contents

For a turnkey led screen for stage rental, you should expect to pay between $2,500 and $8,500 per day for standard indoor corporate stages, and between $6,000 and $16,000+ per day for large outdoor festival concert stages. If you break that down by modular hardware tiles alone, typical indoor panels (like P2.6mm or P2.9mm) run between $60 and $140 per 500x500mm cabinet per day, while high-output outdoor IP65 waterproof panels rent for $85 to $180 per panel per day. A standard multi-day conference rarely charges the full day rate multiplied out; reputable audiovisual production houses operate on a “3-day week” billing rule, meaning a three- to five-day event usually costs about 2.0x to 2.5x the single-day hardware rate.

Have you ever sat through a corporate presentation or stood in front of a festival stage where you had to squint because stage spotlights completely washed out the visuals? Or maybe you saw an executive pacing on stage while their slide deck was stretched sideways like an old funhouse mirror?

We see it happen on stages all the time. An event planner gets a dry-hire quote for an LED screen, looks at the total, and assumes any screen that lights up will look great. Then show day arrives, the room lights dim, the stage spotlights kick on, and the screen either looks like a blinding lamp or flickers with nasty black scan lines whenever anyone takes a photo with their smartphone.

When we are planning a stage production, getting the visual backdrop right is not about picking the most expensive gear in the catalog. It comes down to matching pixel pitch to your front-row seating distance, calculating whether your stage floor can handle ground-stacked weight, and making sure the video control rack has the right processing power. Let’s look past the glossy sales flyers and dig into real rental rates, sizing math, rigging methods, and on-site realities so your stage looks clean and professional from every seat in the house.

What Does an LED Screen for Stage Rental Actually Cost?

When looking at production budgets, stage screens get quoted in two different ways: turnkey stage packages (pre-configured 16:9 widescreen dimensions including processors, ground support, and basic cabling) or custom modular panel builds for wide backdrop banners, split stage wings, or curved stages.

To give you a realistic picture, here is what full-service rental rates look like across North American and European production markets:

Stage Screen CategoryPhysical Dimensions (W x H)Pixel Pitch & EnvironmentTotal Surface AreaTypical Daily Rental RateBest Suited For
Small Presentation Stage10′ x 6′ (3.0m x 1.8m)P1.9mm – P2.6mm Indoor~60 sq. ft$2,200 – $3,600Intimate executive seminars, panel talks, VIP breakout rooms
Standard Ballroom Stage16′ x 9′ (5.0m x 2.8m)P2.6mm Indoor~144 sq. ft$4,500 – $7,200Corporate keynotes, annual general meetings, awards galas
Wide Plenary Stage Backdrop24′ x 10′ (7.3m x 3.0m)P2.6mm – P2.9mm Indoor~240 sq. ft$7,500 – $12,500Major corporate summits, product launches, multi-window presentations
Curved Stage Video Wall20′ x 10′ (6.0m x 3.0m)P2.6mm Concave Indoor~200 sq. ft$8,000 – $14,000Immersive keynote stages, live broadcast sets, virtual backdrops
Mid-Size Outdoor Stage16′ x 10′ (5.0m x 3.0m)P3.9mm IP65 Outdoor~160 sq. ft$5,500 – $9,000Community festivals, sports viewing stages, beer garden screens
Concert Main Stage Wall30′ x 16′ (9.1m x 4.9m)P3.9mm – P4.8mm Outdoor~480 sq. ft$14,000 – $26,000+Major touring concerts, music festivals, stadium stage centerpieces
Mobile Stage Screen Trailer17′ x 10′ (5.2m x 3.0m)P3.9mm Outdoor (Hydraulic)~170 sq. ft$3,800 – $6,800Rapid-setup outdoor stages, marathons, civic street rallies

How the Multi-Day “3-Day Week” Pricing Model Works

If you have a four-day corporate conference running from Tuesday morning through Friday afternoon, does that mean your rental costs four times the daily rate?

Thankfully, no. The live events industry operates almost universally on a “3-day week” billing structure.

  • Day 1: 100% of the baseline daily equipment rate.
  • Day 2: 50% of the daily rate.
  • Days 3 through 7: Typically capped at a flat multiplier of 2.0x to 2.5x the single-day equipment price.

Because the production company only has to prep the flight cases, load the truck, drive to your venue, and mechanically lock the screen together once, leaving the panels standing on your stage deck for two or three extra days costs them very little additional wear. Keep in mind that daily labor for on-site video technicians will still recur for each show day, but the hardware portion drops dramatically.

Pixel Pitch vs. Stage Viewing Distance: The 1mm = 1 Metre Rule

A common mistake in stage production is paying for an ultra-tight pixel pitch that nobody in the audience will actually notice. A producer will look at an equipment quote and think: “P1.5mm sounds much sharper than P2.6mm, so let’s book that for our keynote stage.”

Pixel pitch is the physical measurement in millimeters from the center of one LED diode cluster to the center of the next diode. A smaller number means higher diode density, closer spacing, and a noticeably higher hire bill.

Why does a P1.5mm screen cost so much more than a P2.9mm screen? A P1.5mm cabinet has roughly three times as many microscopic diodes packed onto the circuit board. They run hotter, require delicate handling, and cost rental houses significantly more to maintain.

Viewing Distance Calculation Guide:
Pixel Pitch (in mm) × 1 Metre (3.28 Feet) = Recommended Clean Viewing Distance
• P1.5mm ──> Clean and continuous from ~5.0 feet (1.5 meters)
• P1.9mm ──> Clean and continuous from ~6.2 feet (1.9 meters)
• P2.6mm ──> Clean and continuous from ~8.5 feet (2.6 meters)
• P2.9mm ──> Clean and continuous from ~9.5 feet (2.9 meters)
• P3.9mm ──> Clean and continuous from ~13.0 feet (3.9 meters)
• P4.8mm ──> Clean and continuous from ~16.0 feet (4.8 meters)

Now consider your actual stage layout. At almost any corporate summit or gala dinner, the stage riser is at least 2 to 3 feet high, and the front row of guest seating or VIP dining tables is placed at least 12 to 16 feet away from the stage skirt.

At 15 feet away, human eyes cannot physically resolve the difference between a P1.9mm screen and a P2.6mm screen. You end up spending an extra $2,000 to $4,000 on microscopic pixels that blend into the exact same image to everyone sitting in the room.

My practical rule of thumb on site:

  • Choose P1.5mm to P1.9mm only when presenters or panel guests sit within arm’s reach of the screen, or for high-definition television broadcast studios where cameras zoom in tight on on-screen graphics.
  • Choose P2.6mm to P2.9mm as your reliable baseline for 90% of indoor corporate stages, hotel ballrooms, and church sanctuaries.
  • Choose P3.9mm to P4.8mm for outdoor concert stages, live festival backdrops, and arena perimeters where the crowd stands 20 feet or further back.

Ground-Stacking vs. Flown Truss Rigging: Structural Realities on Stage

How your screen is physically mounted on stage will dictate a massive chunk of your labor budget, setup timeline, and stage floor space.

Stage Rigging Configuration Trade-Offs:
┌────────────────────────────────────────────────────────┐
│ Ground-Stacked Baseplate System                        │
│ • Hardware: Heavy steel base rails, screw jacks, truss │
│ • Pros: Fast build, zero ceiling rigging points needed │
│ • Cons: Consumes 3 to 5 feet of stage deck depth       │
└────────────────────────────────────────────────────────┘
                           VS.
┌────────────────────────────────────────────────────────┐
│ Flown Overhead Truss Rigging                           │
│ • Hardware: Fly bars, 1-ton chain hoists, box truss    │
│ • Pros: Clean stage floor, unobstructed sightlines     │
│ • Cons: Venue rigging point fees, certified rigger cost│
└────────────────────────────────────────────────────────┘

Here is a direct comparison of the three primary ways screens get placed on stage:

Mounting MethodTypical Hardware ComponentsSetup Time RequiredStage Floor ImpactPrimary Cost Variables
Ground-Stacked Base SystemSteel baseplates, ladder truss, rear ballast weights2.5 to 3.5 hoursConsumes 3 to 5 feet of rear stage depthLeveling jacks, stage riser load limits, ballast
Flown from Venue CeilingFly bars, electric chain hoists (1-ton), box truss4.0 to 6.0 hoursZero floor space (completely suspended)Venue rigging fees, union labor, ceiling weight stamps
Ground-Supported Goalpost TrussSelf-climbing truss towers, heavy base outriggers3.5 to 5.0 hoursTakes 4 feet of floor width on each stage sideTower footprint, ballast cubes, motor controls
Hydraulic Mobile TrailerIntegrated trailer chassis, hydraulic lifting mast30 to 45 minutesParked behind or alongside outdoor stageTowing access, level ground footprint, wind anchors

1. The Ground-Stacked Approach

Ground stacking is the standard method for hotel ballrooms and venues where the ceiling cannot support heavy overhead loads.

The build begins with heavy steel base rails placed directly on the stage deck. Each rail is leveled using adjustable screw jacks. Once the bottom tier of panels is plumb, tiles lock together row by row, supported from behind by vertical aluminum ladder trusses and diagonal pipe braces weighted down with 20kg stage weights or sandbags.

  • Watch your stage riser height: If your stage riser is only 12 inches high, attendees sitting past row five will spend the entire session staring at the back of someone’s head instead of your slides. You want a stage deck height of at least 3 to 4 feet so the bottom edge of your visual content clears the room comfortably.
  • Stage deck weight ratings: A 16×9 foot LED wall with baseplates and ballast weighs roughly 1,200 to 1,600 pounds. Make sure your stage risers (like standard 4×8 ft Steeldeck or Stagehand platforms) are properly rated and braced beneath the rear edge of the wall.

2. Flown Truss Rigging (Overhead Suspension)

If you have a large audience in a flat convention hall or an arena, you need the screen elevated four or five feet above the stage deck so everyone has a clear sightline.

The top row of LED cabinets latches into specialized aluminum fly bars. These fly bars are shackled to structural box truss spans hoisted toward the ceiling by electric chain motors (such as CM Lodestars).

  • The venue rigging cost trap: In major convention centers and union hotel halls (especially in cities like Las Vegas, Chicago, New York, or London), external AV companies are legally prohibited from touching the ceiling beams. You must hire the venue’s exclusive in-house union riggers to hang the motor points. That alone can add $1,500 to $4,000 to your invoice, completely separate from your AV vendor’s screen hire quote.

Indoor vs. Outdoor Stage Screens: Why Weatherproofing Changes Everything

Can you take an indoor stage screen and set it up on an outdoor festival stage under a covered roof canopy?

The answer is no.

We see production teams attempt this to shave 15% off their budget, and it almost always ends in disaster. Indoor and outdoor stage panels are engineered for completely different environmental demands.

1. Brightness Output (Nits)

  • Indoor Stage Panels: Output between 800 and 1,200 nits. Inside a dimly lit ballroom, that provides rich contrast and deep black levels. If you run an indoor screen at full 1,200 nits in a dark hall, it will actually blind your audience. But place that same screen outdoors, even under a covered stage roof, and ambient daylight washes out the contrast completely, turning your graphics into a milky gray rectangle.
  • Outdoor Stage Panels: Blast between 4,500 and 6,500+ nits. These screens are engineered to compete directly with midday sunlight. They feature physical black louvers (tiny shades) above each diode that block overhead sun glare, keeping live camera feeds and sponsor logos crisp and legible.

2. Weatherproofing and Ingress Protection (IP Ratings)

Outdoor stage panels carry an IP65 rating across both the front face and rear electronics doors. The LED modules are sealed in waterproof optical resins, power supplies are housed in gasketed compartments, and power connections use locking Neutrik powerCON TRUE1 and etherCON TOP weatherproof connectors.

Indoor stage panels have open ventilation slots to shed heat silently. Morning dew, high coastal humidity, or rain mist blown under a stage canopy will track moisture across the circuit traces, tripping ground breakers and burning out receiving cards mid-performance.

Signal Processing, Refresh Rates, and What Happens Backstage

A stage screen is only as reliable as the video processing rack feeding it. Between your presenter’s laptop and the screen panels sits a dedicated video control rack.

Stage Video Signal Architecture:
[Presenter Laptop / Media Server] ──> (HDMI 2.0 / 12G-SDI)
                                             │
                                             ▼
[Seamless Presentation Switcher] (Analog Way / Barco / Blackmagic)
                                             │
                                             ▼
[LED Video Processor / Sending Card] (NovaStar VX1000 / Brompton Tessera)
                                             │
                      (Shielded Cat6 Gigabit Data Loops)
                                             │
                                             ▼
[LED Stage Panels] (Receiving Cards in Cabinets)

1. Why the 3,840Hz Refresh Rate Is Essential

Will people at your event take photos with their phones? Will your stage be recorded by a professional video crew or live-streamed to a remote audience?

If the answer is yes, you must ensure that your rental panels feature a refresh rate of 3,840Hz or higher.

Cheaper or older display tiles often run at a 1,920Hz refresh rate. To the human eye in the room, the image looks totally fine. But when someone pulls out an iPhone with a fast shutter speed or a broadcast camera films the stage, dark horizontal rolling bars (scan lines and moiré patterns) appear across the screen. High-refresh 3,840Hz driver chips eliminate camera flicker entirely.

2. Video Processing: NovaStar vs. Brompton

  • NovaStar: The workhorse platform for 90% of corporate stages, conventions, and commercial events. Processors like the NovaStar VX600, VX1000, or UHD Jr deliver dependable pixel mapping, low latency, and color calibration at an affordable rental rate.
  • Brompton Technology: The gold standard for high-end concert touring, live broadcast studios, and virtual film production. Brompton Tessera processors offer unmatched color science, sub-frame processing latency, and nuanced low-brightness grayscale control, commanding a higher rental premium.

3. Aspect Ratios and Stage Banner Formats

Standard presentation decks use a 16:9 widescreen aspect ratio (1920×1080 Full HD or 3840×2160 4K UHD).

When you build a modular stage wall, you are locking together 500x500mm square cabinets. If you build a wide stage backdrop that is 12 panels wide by 4 panels high (19.7′ x 6.5′), your physical aspect ratio is roughly 3:1, not 16:9.

What should you do then? If you send a standard 16:9 PowerPoint file directly to a 3:1 screen, your presentation will stretch horizontally, turning circle logos into wide ovals.

This way you can easily handle it: have your AV technician set up the video processor to create a dedicated 16:9 presentation window in the center of the wall, flanked by custom-branded graphic columns on either side. Alternatively, have your graphics team produce slides built specifically to the wall’s custom pixel dimensions.

Power Requirements and Load-In Logistics

Before you sign a contract for a large stage screen, you have to verify two mundane physical factors: electrical power drops and loading dock elevator clearances.

Production Setup Timeline (Standard 16x9 ft Stage Screen):
[07:00] Load-in from venue dock & staging flight cases near stage
   ↓
[07:45] Metering 3-phase power drop & laser leveling base rails
   ↓
[08:30] Interlocking modular cabinets, powerCON & data looping
   ↓
[10:15] Processor boot, canvas mapping & test pattern validation
   ↓
[11:00] Signal switching checks with presenter laptops & media servers
   ↓
[11:45] Client content dry-run, color balancing & final sign-off

1. Power Draw Realities

A standard 16×9 foot indoor stage screen contains around 60 modular panels. Under heavy white graphical loads, that screen draws roughly 25 to 35 amps of continuous power.

You cannot plug an industrial stage screen into standard 15A wall plugs around the ballroom perimeter. Doing so will trip building breakers immediately. You will need a dedicated 30-amp or 50-amp single-phase or three-phase power drop (often supplied via Camlok or twist-lock disconnects) near the stage. Always ask your AV provider for an electrical load sheet early so you can coordinate with the venue electrician.

2. Venue Loading Access and Flight Cases

A 16×9 foot modular screen arrives in 12 to 16 heavy road cases, each weighing between 150 and 200 pounds.

If your event is located in an upper-floor hotel ballroom, those road cases must fit through the venue’s freight elevator and navigate carpeted service hallways. Always check door widths, ramp slopes, and elevator interior dimensions beforehand. If equipment has to be manually carried up stairs, your AV vendor will need to add extra stagehands to your labor bill.

Two Real Field Cases: Corporate Plenary vs. Outdoor Music Stage

To see how these variables come together in practice, let’s look at two contrasting setups handled recently:

Field Production Comparison:
Indoor Leadership Plenary vs. Outdoor Summer Music Stage
Scenario A (Corporate Plenary):
• Venue: Hotel Grand Ballroom, Chicago, IL
• Hardware: 16' x 9' Indoor P2.6mm (Ground-Stacked)
• Challenges: 14-foot ceiling clearance with crystal chandeliers
• Total Package: $5,800 turnkey (Hardware + 2 technicians)
Scenario B (Summer Music Stage):
• Venue: Outdoor City Waterfront Park, Austin, TX
• Hardware: 24' x 13' Outdoor P3.9mm IP65 (Flown Goalpost Truss)
• Challenges: Direct midday sun glare, 22 mph wind gusts, no grid power
• Total Package: $11,500 turnkey (Screen + Ballast + 60kVA Generator + Crew)

Case Study A: The Chicago Corporate Plenary

  • The Brief: A medical software firm needed a stage backdrop to show complex interface dashboards and high-density clinical charts to 450 doctors.
  • The Challenge: The ballroom featured low crystal chandeliers that limited ceiling clearance to 14 feet, eliminating any option to fly a truss overhead. In addition, the service elevator was too shallow for oversized flight cases.
  • How We Solved It: We deployed a 16′ x 9′ ground-supported P2.6mm indoor wall. Panels were packed into compact, double-stacked half-cases that navigated the elevator easily.
  • The Result: We built an ultra-low-profile rear ladder frame anchored behind dark stage drapery. By running the NovaStar processor at 65% brightness and tuning the color temperature to a warm 6500K, the slides looked integrated into the stage design, delivering crisp readability from the back row without blinding the speakers on stage.

Case Study B: The Austin Outdoor Music Stage

  • The Brief: An outdoor summer music festival needed a main stage backdrop to run live camera feeds (IMAG) of performers, dynamic motion graphics, and sponsor reels throughout an open-air weekend.
  • The Challenge: The site faced open water with unpredictable wind gusts, full exposure to midday sun, and zero municipal power hookups.
  • How We Solved It: We deployed an outdoor P3.9mm display rated at 6,000 nits, suspended from an engineered aluminum goalpost truss structure.
  • The Safety Protocol: To manage wind loads, we anchored each vertical truss column with two 1,000-liter water ballast tanks (providing over 4,000 lbs of downward ballast per side) and installed a digital anemometer on the top beam. The system was powered by a whisper-quiet 60kVA mobile diesel generator positioned 60 feet away behind sound baffles. The 6,000-nit output punched cleanly through intense afternoon glare, and when an evening rain shower passed through, the IP65-sealed panels operated without interruption.

Overlooked Contract Fees in Stage Screen Proposals

When comparing proposals from different AV companies, looking only at the total price on page one can lead to budget surprises later. Always inspect the terms and conditions for these four common line items:

  1. Dedicated On-Site Video Operator (V1 Tech): Some budget proposals include delivery and basic assembly, but leave your internal staff to operate the system during the live show. If a keynote speaker’s laptop resolution freezes or a video signal desyncs, you have no technical support. Always ensure your contract includes a dedicated video technician stationed behind the control console throughout the event (typically $450 to $750 per day).
  2. Venue Power Tap and Electrical Admin Fees: Venues regularly charge an administrative utility connection fee to tap into their high-amperage electrical panels. Request an electrical draw calculation from your AV provider so you can coordinate with the venue manager without purchasing an unnecessarily large power drop.
  3. Elevator and Freight Access Surcharges: If your venue lacks a street-level loading dock and requires moving 20 heavy flight cases through service elevators, across carpeted hallways, or up flights of stairs, providers often charge extra for the additional stagehands required.
  4. Emergency Custom Media Scaling: If your screen build uses a unique aspect ratio and your graphics team arrives with standard 16:9 slides that stretch or crop, the on-site technician will need to manually scale the media. If that work has to be done on show morning, it often triggers an extra media management fee.

Content Preparation Guide for Large Stage Screens

You can rent a well-engineered screen system, but if your presenters bring poorly formatted presentation files, the overall stage appearance will suffer.

  • Design with True Dark Backgrounds: LED screens create deep black tones by turning off individual diodes entirely. Using dark charcoal, deep navy, or true black slide backgrounds produces high contrast that makes white text and graphics pop, while all-white slides can act like a giant fluorescent light panel, washing out presenters on stage.
  • Ensure High Resolution for Embedded Media: If you are displaying images or company logos on a large stage screen, source vector files (EPS or SVG) or high-resolution PNG assets. A small 72 DPI image copied from a website will appear noticeably pixelated when stretched across a 16-foot display.
  • Choose Bold, Legible Typography: Avoid ultra-thin or delicate serif fonts for presentation slides. Use bold sans-serif typefaces (like Helvetica, Roboto, or Arial) with a minimum font size of 24 to 28 points for body copy to ensure effortless readability from the back of the room.

FAQ

1. How much does an led screen for stage rental cost for a one-day event?

For a standard indoor corporate stage screen (around 16×9 feet), the turnkey daily rental cost typically ranges from $4,500 to $7,200. Smaller presentation screens (10×6 feet) start around $2,200 to $3,600, while large outdoor concert stages or arena video walls generally run from $8,500 to $20,000+ per day depending on rigging, ballasts, and generator support.

2. What pixel pitch should I choose for an indoor stage screen?

For most corporate auditoriums and hotel ballrooms, P2.6mm is the industry standard sweet spot. It provides pin-sharp clarity for slides and spreadsheets from an audience viewing distance of 8.5 feet (2.6 meters) without the steep cost premium of P1.5mm or P1.9mm broadcast-grade panels.

3. Can I use an indoor stage screen outdoors under a covered roof?

No. Indoor screens only produce 800 to 1,200 nits of brightness, which ambient outdoor daylight will wash out, leaving the display pale and hard to see. Furthermore, indoor panels lack the IP65 weather-sealed enclosures required to protect delicate circuitry from humidity, morning condensation, and wind-blown rain mist.

4. How long does an AV crew need to assemble a modular stage screen?

A standard indoor 16×9 foot ground-supported stage screen takes two experienced technicians 2.5 to 3.5 hours to mechanically assemble, cable, map, and test. Flown overhead truss systems or outdoor walls with heavy ballast anchoring generally require 4 to 6 hours.

5. What kind of electrical supply is needed for a modular stage screen?

While small monitors under 85 inches run on standard 15A wall outlets, a full modular stage screen requires a dedicated 30-amp, 50-amp, or 100-amp single-phase or three-phase power drop. For outdoor parks or fields without permanent power connections, you will need a mobile whisper-quiet diesel generator fitted with an electronic voltage regulator.

6. Will the stage screen flicker in smartphone photos or recorded video?

Not if you select panels with a sufficiently high refresh rate. Always confirm that your equipment contract specifies a refresh rate of 3,840Hz or higher. Lower refresh rates (such as 1,920Hz) can cause dark horizontal scan lines and flickering moiré artifacts on camera feeds and mobile phone photos.

7. How does multi-day rental pricing work for longer conferences?

Audiovisual hire companies use a standard “3-day week” billing structure. A two-day event is billed at roughly 1.5x the single-day rate, while a three-to-seven-day event is capped at 2.0x to 2.5x the base daily price. You do not pay the full daily rate for each consecutive day of an event.

8. What is the difference between an LED stage screen and a projection screen?

An LED stage screen generates direct light from millions of tiny diodes, delivering punchy contrast and vivid colors even in brightly lit rooms with full stage spotlights. A projector beams light onto a reflective fabric screen, which gets washed out whenever ambient room light or stage fixtures hit the surface.

9. Can I plug a presenter laptop directly into the stage screen?

Yes. The video processor acts as the bridge between your source hardware and the screen. You connect your laptop to the processor or seamless switcher using standard HDMI, DisplayPort, or USB-C connections, and the hardware automatically scales your signal to fit the display’s native pixel canvas.

10. How far in advance should I reserve an LED screen for stage rental?

For standard corporate events during normal business months, booking 3 to 4 weeks in advance is usually sufficient to secure equipment and crew. However, for peak event windows—such as May through July for outdoor summer festivals or September through November for annual conferences—inventories book up 2 to 3 months ahead. Reserving early secures your preferred hardware and prevents expedited transport charges.

When you are ready to book a stage screen for your upcoming event, take a close look at your room dimensions and where your closest attendee will actually sit. Choose your pixel pitch based on that real-world viewing distance rather than paying extra for microscopic diodes you don’t need, confirm power hookups and loading dock access with the venue manager early on, and make sure your agreement includes a trained video technician behind the control console on show day. Taking care of those core basics in advance guarantees your stage presentation looks vibrant and runs without interruption from the opening slide to the final wrap.

Disclaimer
Product information, specifications, and prices are provided for reference only and may vary based on project requirements and market conditions. Brand names mentioned are for comparison purposes only and do not imply any affiliation.For the most accurate product details and pricing, please refer to your specific project requirements.

GET YOUR CUSTOM LED DISPLAY QUOTE

Tell us your basic requirements and receive a quick quotation from our LED experts.

SOLICITE UM ORÇAMENTO PERSONALIZADO PARA SEU PAINEL DE LED

Informe seus requisitos básicos e receba rapidamente um orçamento de nossos especialistas em painéis de LED.

Solicite su presupuesto personalizado de pantalla LED

Indíquenos sus requisitos básicos y reciba rápidamente un presupuesto de nuestros expertos en pantallas LED.