BLOG

 

What is the actual led screen rental price for events?

Table of Contents

For an indoor corporate event or conference, a realistic led screen rental price ranges between $1,500 and $3,800 per day for an entry-level modular video wall spanning 10×6 ft to 13×8 ft (using P2.6 or P2.9 pixel pitch). If you are building a larger keynote stage display, such as a 16.4×9.8 ft (5x3m) or 20×11 ft widescreen wall, turnkey rental rates generally sit between $4,800 and $9,200 per day. For massive outdoor festival stages, open-air sporting events, or stadium concert backdrops requiring high-output weatherproof panels, budgets scale from $8,500 to $22,000+ per day. On an individual equipment level, standard 500mm × 500mm (roughly 20×20 inch) modular LED tiles rent for $65 to $140 per panel, per day, depending on diode pitch, refresh rate, and whether you require ground stacking hardware or flown ceiling rigging.

Have you ever opened an audio-visual quote for an upcoming conference, stared at the bottom line, and wondered why two vendors quoting the exact same screen dimensions can be $5,000 apart? It happens all the time. One production house sends a bare-bones dry-hire equipment rate, while another includes dedicated 4K processors, ground-support trussing, on-site video engineers, and union delivery logistics.

When you plan visual staging for an event, you need to understand how quotes are constructed so you can negotiate effectively, protect your budget, and avoid paying for high-end technical specs your audience will never even see.

The Modular Tile Unit Math: How Quotes Are Built

Unlike consumer televisions, large video displays are never transported as a single massive piece of glass. They are assembled on site from interlocking modular cabinets called panels or tiles.

The global staging industry standard footprint is 500mm wide by 500mm tall (1.64 ft × 1.64 ft), with some rental houses stocking 500mm × 1000mm panels to speed up vertical builds on massive outdoor festival walls.

Master Pricing Formula:
Total Invoice = (Panel Count × Daily Tile Rate) + Master Video Processor + Rigging Structure + Crew Labor + Logistics

Because these tiles lock together with mechanical quick-turn latches, you can build flat backdrops, curved video walls, or vertical visual columns. Sticking to a standard 16:9 widescreen aspect ratio remains the smartest choice for 95% of events because your PowerPoint slide decks, keynote graphics, and video playback files map natively without requiring custom media servers, custom pixel mapping, or image letterboxing.

Let’s calculate the real numbers for a standard corporate stage size: a 16.4 ft wide by 9.8 ft tall (5m × 3m) main session wall.

  • Horizontal Width: 5,000mm ÷ 500mm per panel = 10 panels wide
  • Vertical Height: 3,000mm ÷ 500mm per panel = 6 panels high
  • Total Panel Count: 10 × 6 = 60 modular panels

If a staging house charges an average rate of $80 per panel per day for P2.6 indoor tiles:

  • Panel Hardware Subtotal: 60 panels × $80 = $4,800/day
  • Master Video Processor / Scaler: 1× NovaStar UHD 4K or Brompton unit = $450 – $750
  • Ground Support Hardware: Aluminum baseplates, rear ladder truss, kickers, ballast = $350 – $550
  • Signal Cabling & Power Distro: Shielded Cat6, tactical fiber, PowerCON True1 runs = $150 – $300
  • Core Equipment Subtotal: $5,750 – $6,400 (before crew labor and transit)

This equipment baseline gives you clear insight into the quote. When a vendor hands you an estimate of $9,000, you can calculate the per-panel cost and immediately spot where labor, hardware margins, or logistics may be padded.

LED Screen Rental Cost & Dimension Benchmarks

To help you draft an accurate event budget, here is a practical look at what staging companies charge for common modular screen configurations across North American and European corporate and entertainment markets.

Event Application & SetupDimensions (W × H)Recommended Pixel PitchEstimated Panel Count (500×500mm)Typical 1-Day Turnkey CostMulti-Day Show Rate (2–3 Days)
Trade Show Demo Pod / Kiosk8.2 ft × 4.9 ft (2.5m × 1.5m)P1.9 – P2.6 Indoor15 panels$1,600 – $2,600$2,500 – $3,900
Wedding Backdrop / Private Gala11.5 ft × 6.5 ft (3.5m × 2.0m)P2.6 – P2.9 Indoor28 panels$2,400 – $3,800$3,600 – $5,700
Corporate Keynote / Ballroom16.4 ft × 9.8 ft (5.0m × 3.0m)P2.6 Indoor60 panels$5,200 – $8,200$7,800 – $12,500
Wide Panoramic Stage Backdrop26.2 ft × 9.8 ft (8.0m × 3.0m)P2.6 – P2.9 Indoor96 panels$8,500 – $13,500$13,000 – $20,000
Dual Stage IMAG Screens (Pair)13.1 ft × 8.2 ft each (Flown)P2.9 – P3.9 Indoor80 panels total$7,500 – $11,500$11,500 – $17,000
Outdoor Festival / Live Concert23.0 ft × 13.1 ft (7.0m × 4.0m)P3.9 – P4.8 IP65 Outdoor112 panels$9,500 – $16,000$14,500 – $24,000
Stadium Tour / Large Stage Wall32.8 ft × 16.4 ft (10.0m × 5.0m)P3.9 IP65 Outdoor200 panels$16,500 – $28,000+$25,000 – $42,000+

Note: Staging companies do not multiply the single-day equipment price by three for a three-day conference. Standard AV rate cards apply a sliding scale multiplier—typically 1.5× the daily equipment rate for a 2 to 3-day event, and 2.5× to 3× for a full 7-day week. On-site technician labor is billed separately based on actual show hours worked.

Decoding Pixel Pitch: Never Pay for Pixels Your Audience Cannot See

The easiest way to blow your production budget is choosing a pixel pitch that is much tighter than your venue actually requires.

Pixel pitch, denoted by the letter P followed by a millimeter measurement, indicates the physical center-to-center distance between neighboring LED diodes. A P1.9 panel has diodes spaced 1.9mm apart; a P3.9 panel spaces them 3.9mm apart. The smaller that physical gap, the more microscopic diodes are packed onto each tile, which dramatically increases manufacturing and rental costs.

Viewing Distance Calculation:
Minimum Optimal Viewing Distance (in feet) ≈ Pixel Pitch (in mm) × 3.28 ft (1 meter)
[Audience Seated 6–8 ft Away]   ───> P1.9 to P2.6 (Sharp slide text, zero visible diode grid)
[Audience Seated 10–14 ft Away]  ───> P2.6 to P2.9 (The corporate ballroom sweet spot)
[Audience Seated 18–25+ ft Away] ───> P3.9 to P4.8 (Music festivals, live arena stages)

The Three Common Rental Tiers

  • P1.5 to P1.9 (Ultra-Fine Pitch): Rents for $120 to $180 per panel. You only need this if your audience stands within 5 to 7 feet of the display. It suits luxury retail showcases, broadcast television studios where studio cameras shoot tight close-ups without optical moiré interference, or executive presentation rooms displaying dense data sheets.
  • P2.6 to P2.9 (The Corporate Standard): Rents for $75 to $110 per panel. This is the true workhorse of corporate staging. From 8 to 10 feet away, slide typography, fine branding logos, and 4K video clips look solid, seamless, and pin-sharp.
  • P3.9 to P4.8 (Stage & Outdoor Workhorse): Rents for $55 to $85 per panel. If your presentation stage sits inside a long convention hall or church sanctuary where the closest row of seats is 15 feet away, a P3.9 display looks visually identical to P2.6 because human eyesight cannot resolve the tighter spacing at that distance.

“A common staging error is paying for ultra-fine pitch on high stages. If the nearest audience seat sits 20 feet back from the stage riser, renting P1.9 instead of P2.9 burns 30% of your equipment budget on resolution that human eyes physically cannot perceive.”

Indoor vs. Outdoor Video Walls: Technical and Cost Differences

Placing an indoor screen outdoors—even under a three-sided marquee tent—is an expensive risk. If your event takes place in the open air, you need to budget for specialized outdoor-rated inventory. Outdoor LED walls command a 20% to 35% premium over indoor systems due to engineering requirements in two areas: light output and environmental protection.

Feature & SpecificationIndoor Staging PanelsOutdoor Staging Panels (IP65)Operational Impact
Luminance (Brightness)800 – 1,400 Nits4,500 – 7,500+ NitsOutdoor screens fight direct sunlight; indoor screens appear washed out in daylight.
Ingress Protection (IP)IP30 (Non-waterproof)IP65 (Front & Rear sealed)Outdoor panels feature silicone potting to handle torrential rain and blowing dust.
Structural RiggingLightweight baseplates & sandbagsEngineered truss, steel bases, IBC totesOutdoor screens act like sails; wind requires heavy ballast counterweights.
Module Service AccessMagnetic front-service toolsRear latch / mechanical screwsOutdoor seals require secure physical compression to maintain water resistance.
Power Consumption200W – 350W max per m²600W – 950W max per m²High-brightness diodes draw significantly more amperage, requiring generators.
Average Daily Tile Cost$65 – $110 per panel$85 – $145 per panelWeather seals, cooling fans, and high-output diodes increase hardware costs.

Hardware Construction: Magnesium Cabinets and Refresh Rates

Not all modular LED tiles are built the same way. When reviewing an equipment list from a production vendor, looking into cabinet construction tells you whether you are getting reliable staging hardware or dated, heavy inventory.

Anatomy of a Professional Rental LED Panel:
┌────────────────────────────────────────────────────────┐
│ [Front Face] 4x Magnetic Surface Modules (SMDs)        │
│ ────────────────────────────────────────────────────── │
│ [Chassis] Die-Cast Magnesium Alloy (15-18 lbs total)   │
│ ────────────────────────────────────────────────────── │
│ [Curving Locks] Built-in Angle Adjustment (-5° to +10°)│
│ ────────────────────────────────────────────────────── │
│ [Rear Core] Tool-Free Detachable Central Power/Hub Box │
│ ────────────────────────────────────────────────────── │
│ [Connectors] Neutrik powerCON TRUE1 + etherCON Data In │
└────────────────────────────────────────────────────────┘
  • Die-Cast Magnesium vs. Aluminum Alloy: Older or budget rental panels use heavier die-cast aluminum frames weighing 22 to 26 lbs (10 to 12 kg) per 500x500mm tile. Modern high-tier staging panels (such as ROE Visual Carbon series, Absen Polaris, or Infiled DB series) are manufactured from die-cast magnesium alloy, dropping panel weight to 15 to 18 lbs (7 to 8 kg). Saving hundreds of pounds across an entire wall helps you stay under venue ceiling load limits.
  • Camera Refresh Rates (Anti-Moiré and Anti-Flicker): If your event involves professional broadcast cameras, live streaming, or stage photography, panel refresh rates are critical. Low-grade rental panels feature refresh rates of 1,920Hz. While this looks smooth to the naked eye, television cameras shooting at standard shutter speeds (1/50 or 1/100) will capture dark rolling horizontal black scan bars and moiré rainbow patterns. For camera-facing stages, demand panels with a refresh rate of 3,840Hz or 7,680Hz.
  • Magnetic Front-Service vs. Rear-Service Modules: Each 500x500mm panel consists of a structural cabinet housing four smaller 250x250mm magnetic modules. On front-service panels, if a diode gets damaged mid-event, a technician uses an electronic vacuum tool to pull the faulty module straight off the front and pop in a fresh replacement in under 45 seconds without disturbing adjacent tiles.

Ground-Stacking vs. Flown Ceiling Rigging: Structural Considerations

How your screen will stand inside the venue influences both your equipment bill and your labor charges.

Ground-Stack System                          Flown (Suspended) System
┌───────────────────────────┐                ══════════════════════════════ (Venue Steel Beams)
│                           │                       │               │
│      Modular LED Wall     │                       ▼ (Chain Hoists)▼
│                           │                ┌───────────────────────────┐
├───────────────────────────┤                │                           │
│ Aluminum Baseplate &      │                │      Modular LED Wall     │
│ Rear Ladder Truss Bracing │                │                           │
└───────────────────────────┘                └───────────────────────────┘
• Rests directly on stage/floor              • Floats cleanly above stage floor
• Fast build, zero ceiling fees              • Requires venue rigging points ($300-$600/pt)
• Occupies 3-4 ft of stage depth             • Preserves 100% of stage floor space

1. Ground Stacking

The screen rests on heavy aluminum or steel baseplates placed on the stage deck or venue floor. Vertical ladder truss runs up the rear of each panel column with diagonal pipe bracing weighted down with sandbags or steel ballast plates.

  • The Advantage: Fast assembly, completely self-supporting, and eliminates venue ceiling rigging charges.
  • The Catch: It consumes roughly 3 to 4 feet of stage depth. Furthermore, if your audience sits on a flat floor without risers, attendees past the third row will have their view blocked by people sitting in front. You usually need to build 2 to 3-foot stage risers under the wall to elevate the bottom of the screen.

2. Flown Rigging (Suspended from the Ceiling)

Specialized rigging fly-bars lock onto the top row of panels, which are suspended from overhead ceiling beams using electric chain hoists.

  • The Advantage: The screen floats cleanly above the stage, ensuring clear sightlines across an audience of hundreds, while keeping the stage surface completely open for presenters and furniture.
  • The Catch: Overhead rigging introduces structural liability. Venues mandate that ceiling attachments be handled by their internal certified riggers. Venues charge a rigging point fee (often $250 to $600 per hang point), and a standard 16-foot wall requires 2 to 4 points.

Signal Architecture & Control: Preventing Live Show Blackouts

An LED screen is only as dependable as the video distribution path driving it. A laptop should never be connected straight to an LED sender via a consumer HDMI cable; if the computer goes to sleep, changes resolution, or gets unplugged, the entire stage goes black in front of your audience.

Professional Video Signal Distribution Chain:
[Main Keynote Laptop]   ──(HDMI)──┐
                                  ▼
[Backup Keynote Laptop] ──(HDMI)──> [Seamless Presentation Switcher] ──(12G-SDI)──> [Master LED Processor]
                                  ▲    (Barco S3 / Roland V-60)                     (NovaStar / Brompton)
[Live SDI Camera Feed]  ──(SDI)───┘                                                            │
                                                                                               ├── Port A (Primary Run)
                                                                                               └── Port B (Redundant Loop)
  1. The Master Video Processor: Dedicated controllers like the NovaStar MCTRL4K, NovaPro UHD Jr, or Brompton Tessera SX40 ingest the video feed, map the pixels to physical panel coordinates, and store factory color calibration profiles.
  2. Closed Redundant Data Loops: Professional technicians always configure a closed redundant loop:
    • Port 1 on the processor feeds data into Panel #1 and daisy-chains sequentially through the wall.
    • Port 2 connects directly from the processor to the final panel in reverse.
    • If someone backstage kicks a network cable loose during a presentation, the processor detects the break in under one millisecond and pushes signal from the reverse direction. The screen doesn’t drop a single frame.
  3. Seamless Video Switchers: Running your source laptops through an external switcher (such as a Barco E2/S3 or Roland V-series) allows the video engineer to smoothly transition between presenter slides, sponsor videos, and live camera feeds with zero visual glitches or frozen desktop screens.

Step-by-Step Procedure: How to Spec, Calculate, and Rent an LED Screen

Following a structured procedure prevents technical surprises and keeps your production on schedule.

Step 1: Map Room Sightlines      ──> Measure distance to front row, back row, and ceiling height
Step 2: Calculate 500mm Grid     ──> Target width and height in meters divided by 0.5m
Step 3: Draft Technical RFP      ──> Define exact pixel pitch, mounting method, and inputs
Step 4: Lock In Matching Diode   ──> Require single batch binning plus 10% on-site spares
Step 5: Run Pre-Show Color Check ──> Test pure white, pure black, and 16:9 presentation slides
  1. Measure audience sightlines and ceiling clearance: Measure the distance from the stage to the nearest attendee, the distance to the farthest seat in the back corner, and the floor-to-ceiling clearance. If your hotel ballroom has an 11-foot ceiling, an 8-foot tall screen leaves only 3 feet of clearance off the floor, meaning attendees behind row three will have their view blocked unless you redesign the stage layout.
  2. Calculate panel count on a 500mm grid: Divide your target width and height in meters by 0.5m. For example, a 5.0m wide by 3.0m tall wall equals 10 panels wide by 6 panels high, totaling 60 panels in a native 16:9 widescreen ratio.
  3. Draft a technical RFP: Provide exact technical parameters to vendors: screen dimensions, aspect ratio, required pixel pitch range (e.g., P2.6 to P2.9), mounting method, input signal counts, and strict load-in/rehearsal schedules.
  4. Demand a single matching diode batch: LED diodes vary slightly in brightness and color hue across different manufacturing runs (known as diode binning). If a rental company mixes panels from two different manufacturing batches on the same screen, your display will look like a patchy checkerboard with mismatched pink and green color casts. Insist on a single matching production batch for all primary panels, plus a 10% spare parts allocation stored on-site in the road cases.
  5. Oversee rehearsal color and signal checks: During setup day, have the lead video technician display a solid white screen, a solid black screen, and primary color test patterns. Inspect the wall for dead pixels, misaligned cabinet seams, and edge banding. Run your slide presentation to confirm that fine typography and financial figures are sharp and legible from the back of the room.

Real-World Case Study: 16.4×9.8 ft Ballroom Setup Invoice

To show how an actual invoice comes together, here is an itemized look at a full-service setup for a 16.4 ft × 9.8 ft (5m × 3m) P2.6 indoor corporate wall for a 2-day conference:

Invoice Line ItemDescription & QuantityDaily Subtotal2-Day Total (1.5x Equipment Rate)
LED Video Panels60× P2.6 Indoor Tiles (500×500mm, NovaStar A8s)$4,800$7,200
Sending Processor1× NovaStar UHD 4K Video Processor / Controller$450$675
Ground Support RigHeavy-Duty Base Plates, Rear Ladder Truss & Ballast$350$525
Signal & CablingTactical Fiber, Cat6 Shielded Runs, PowerCON Distro$150$225
Dedicated Tech (V1)1× Certified Video Engineer (Setup, Rehearsal, Show, Strike)$850$1,700
Stagehand Labor2× Hands for 4-Hour Load-In and 3-Hour Strike$700 (Flat)$700
Logistics & DeliveryRound-Trip Dedicated Box Truck Transport$450 (Flat)$450
Estimated Pre-Tax Total$11,475

Notice that the equipment itself was $8,625 for the two-day stretch, while the skilled crew, transport, and structural support made up the remaining $2,850. Knowing this complete layout protects you from budgeting solely for the screen and running out of money before labor is covered.

Operational Q&A: Addressing Critical Field Dilemmas

When we use modular video walls in hotel ballrooms and convention venues, unforeseen room constraints can quickly slow down setup day if not planned for in advance.

What should you do about venue power distribution?

A standard 16×10 ft stage screen draws between 20 and 35 Amps of 208V power (or multiple dedicated 20A 110V circuits). You cannot plug a commercial stage wall into random wall sockets around the room without tripping circuit breakers.

What should you do then?

Coordinate with the venue facility manager during pre-production to order an isolated 30A or 50A 3-phase power drop (Cam-Lok or CEEform) right behind the stage. Dedicated power isolates your screen from catering warmers, coffee machines, or stage audio amplifiers that can introduce electrical hums or trip shared circuit breakers.

What happens if presenters bring slides in legacy 4:3 format?

If a speaker shows up with slides built in legacy 4:3 square format instead of 16:9 widescreen, displaying them directly will stretch the images horizontally, making logos and people look wide and distorted.

Have your video engineer configure the presentation switcher to display the 4:3 slides centered on the screen with branded conference graphics filling the left and right borders (pillarboxing). That does the trick and keeps the presentation looking intentional.

How do you handle dead pixels that appear right before showtime?

Because modular panels feature front-magnetic modules, fixing a damaged diode cluster does not require taking down the entire wall.

Your on-site technician can grab a matching spare module from the road case, place a vacuum extraction tool against the damaged 250x250mm module, pull it forward off the frame, and snap a new module into place. The receiving card automatically recalibrates the fresh module in under 60 seconds without disrupting rehearsals.

Strategic Advice: How to Cut 25% Off Your Rental Bill

If your initial AV production quote stretches your event budget past its limit, you don’t have to settle for a small, underwhelming screen. Use these practical adjustments to trim your total spend:

  1. Relax your pixel pitch by one increment: Stepping from a P2.6 to a P2.9 panel saves around 15% to 20% on tile costs, and from 12 feet away, the difference is practically invisible to the human eye.
  2. Opt for ground-stacking on stage risers: If the venue ceiling is under 14 feet, skip the flown rigging. Renting standard 4×8 ft stage decks to lift a ground-stacked wall two feet off the floor gives you great visibility while bypassing venue ceiling rigging point charges.
  3. Schedule daytime load-ins: Loading in equipment at 11:00 PM on a Sunday triggers overtime and night differential penalties for stagehands and technicians. Try to negotiate load-in access during normal business hours on the afternoon prior to your show.
  4. Lock in a standard 16:9 canvas: Avoid designing non-standard, ultra-wide aspect ratios unless your budget accommodates custom media mapping and multi-layer processors. Standard 16:9 aspect dimensions run natively from standard laptops and scalers with zero fuss.

FAQ

1. What is the typical led screen rental price per day?

Most turnkey indoor setups range between $1,500 and $4,500 per day for screens spanning 10 to 14 feet wide. Larger conference stage walls or dual-screen ballroom packages typically cost between $5,000 and $10,000+ per day, depending on screen dimensions, pixel pitch, and rigging complexity.

2. Can we dry-hire modular panels and assemble the wall ourselves?

Almost no professional AV staging company will dry-hire modular LED panels without sending their own trained technician. The surface-mounted diodes (SMDs) along panel corners are fragile; knocking two tiles together during assembly can easily shear off dozens of pixels, resulting in thousands of dollars in circuit repair bills. Rental houses require certified technicians on-site to handle assembly, signal mapping, and teardown.

3. How does multi-day rental pricing work for conferences?

Rental houses apply a sliding scale multiplier rather than billing each day at 100%. A typical 2-to-3 day conference equipment hire is billed at roughly 1.5× to 1.8× the single-day equipment rate. On-site technician labor, however, is billed separately based on actual hours worked each day.

4. What is the standard viewing distance for a P2.6 indoor screen?

For a P2.6 screen, the optimal minimum viewing distance is approximately 8 to 9 feet (2.6 meters). Beyond this distance, the human eye cannot resolve the individual pixel boundaries, making the video image appear completely seamless and continuous.

5. How long does it take an AV crew to assemble an indoor video wall?

A standard 16×10 ft ground-stacked indoor wall typically takes 2.5 to 4 hours for a two-person crew to build, cable, calibrate, and test with video sources. If the wall is being flown from overhead ceiling points, add 1.5 to 2 hours for venue riggers to set the hoists, balance the load, and fly the truss to trim height.

6. What power connections do I need at the venue for an LED wall?

A standard 16.4 ft × 9.8 ft indoor LED screen typically draws between 20 and 35 Amps of 208V power. You cannot run a screen of this size off standard domestic wall sockets without tripping the circuit breaker. You must arrange for a dedicated 30A or 50A 3-phase power drop (Cam-Lok or CEEform connection) positioned near the stage.

7. What file formats should we supply for presentation graphics?

Export all static slides and video backdrops in a standard 16:9 widescreen ratio (1920×1080 Full HD or 3840×2160 4K UHD). Render video files using the MP4 or MOV container with an H.264 or ProRes 422 codec at 30 or 60 progressive frames per second. Keep bitrates between 20 and 40 Mbps for artifact-free motion playback.

8. Does the LED screen rental quote include audio?

No. An LED video wall is strictly a visual display surface and contains no built-in speakers. If your event involves speech, background music, or video audio, you must ensure your production proposal includes a dedicated PA sound system (speakers, wireless microphones, mixing console) along with appropriate stage lighting.

9. What is the difference between indoor and outdoor rental panels?

Indoor panels are optimized for close viewing and high color accuracy, featuring brightness levels between 800 and 1,400 nits and fine pixel pitches (P1.5 to P2.9). Outdoor panels feature high-current diodes producing 4,500 to 7,500+ nits to overpower direct sunlight, along with IP65 watertight seals and wind-resistant chassis designs that can operate safely in heavy rain.

10. How far in advance should I reserve an LED display?

For peak spring and autumn conference seasons (March to May and September to November), you should confirm your equipment booking at least 4 to 8 weeks in advance. Quality rental inventory with matching diode bins books out quickly, and late bookings frequently trigger rush cross-rental shipping charges to freight panels in from other warehouses.

When evaluating your quotes, focus on matching the pixel pitch to your actual seating distance rather than simply buying the highest resolution available. In practical event setups, pairing a dependable P2.6 or P2.9 ground-supported display with a clean redundant data loop and an experienced video technician will deliver a crisp, vibrant visual backdrop that keeps your attendees focused on your message while keeping your production budget firmly under control.

Disclaimer
Product information, specifications, and prices are provided for reference only and may vary based on project requirements and market conditions. Brand names mentioned are for comparison purposes only and do not imply any affiliation.For the most accurate product details and pricing, please refer to your specific project requirements.

GET YOUR CUSTOM LED DISPLAY QUOTE

Tell us your basic requirements and receive a quick quotation from our LED experts.

SOLICITE UM ORÇAMENTO PERSONALIZADO PARA SEU PAINEL DE LED

Informe seus requisitos básicos e receba rapidamente um orçamento de nossos especialistas em painéis de LED.

Solicite su presupuesto personalizado de pantalla LED

Indíquenos sus requisitos básicos y reciba rápidamente un presupuesto de nuestros expertos en pantallas LED.